Specifications:
Capacity: (2) Tons : 14.5 kW : 50.9
Compressor: HP : 15 Type : Digital Scroll
Process Pump
HP : 3 GPM : 36 PSI : 55
Type : Centrifugal
Construction : Stainless Steel
Automatic Low Flow Bypass: : Standard
Air-Cooled Condenser: Type : Fan CFM : 15,000 (3) Ambient : 95°F
Refrigerant: Type : R-410A
Full Load Amperage (4): 230/3/60 : 86.6 460/3/60 : 43.3 575/3/60 : 35.0
Reservoir Capacity: Holding : 65 gal Lid : Standard Auto Make-Up : Optional
Process Connections: To Process : 2" From Process : 2" Make-Up : 1/2"
Dimensions: Height : 66" Width : 59" Depth : 59"
Weight (5): Shipping : 2,300 lbs

Specifications

Power Type
Electric
Max BTU/KW
15
Max Ton
15
Volts
460
Weight
2300

Specification Notes:
1. Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
2. Tons capacity at 12,000 BTU/ton per hour @ 50°F LWT @ " 115°F condensing temperature. Capacities may be +/- 5% as reserved by the compressor manufacturer. Operating at temperatures below 50° will reduce chiller capacity. The minimum recommended operating temperature when no glycol is used is 48°F.
3. Design ambient conditions. Loss of capacity and/or difficulty operating will occur at higher ambients. Minimum recommended ambient is 60°F.
4. Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring.
5. Approximate unit weight crated for shipment.
Options:
Refrigerant Circuit
Centrifugal Blower
Damper Assembly (used with centrifugal blowers)
Air Inlet filter and protection screen
Electrical
Emergency Stop Button
UL listed electrical sub panel
Coolant Circuit
Overhead Piping Kit
Reverse Flow ... gravity return to open tank
Process Line Shut Off Valves
Larger process pumps
Warranty
Extended Compressor Warranty

Contact Us